Leader in Integrated Security Since 1962    


  Security
Management
  Control
  lntegration

800-544-9591
 


Logo YPS Integrated Systems:  Fire Alarms, Intrusion Detection/Security Alarms, Access Control, Video Surveillance Camera Systems,  Click logo to go to YPS Home Page              YPS Integrated Systems, BOSCH Certified Security Dealer
 

WELCOME!

 YPSintsys.com  


  REVIEW:  6-30-2008 

YPS Home Page

 
Location >
  
AUTOMATIC FIRE DETECTION

Serving OHIO ONLY for Fire Alarm Systems

fire alarm systems ohio, fire detection

 
Automatic Fire Detection - Fire Alarm Systems
Sales, Installation, ul mONITORING, & Service
OHIO Licensed certified testing and inspection of any fire alarm system in the state of ohio - see coverage area

  •  Intelligent Fire Signature Recognition 

  •  Programmable Flexibility

  •  Fire Alarm System Integration with Access Control Systems and Security Systems

Click MAP ICON for full size YPS Service Areas Map:
Fire Alarm Systems
Click for large map of Local & Wider Service Areas of YPS Integrated Systems for Fire Alarm Systems & Integrated Systems

Fire Alarm Services
City & County LIST

OHIO service area


Security,
Management, &
 Control Systems

Intrusion Detection
Fire Detection
Video Surveillance
Access Control
U.L. Central Station


YPS CLIENTS -
See more about fire alarms at:
CLIENT SERVICES


About Us +
SALES Requests
Your Comments

 

YPS LOCAL
Fire Alarm
Service Areas

 OHIO Cities:
Ashtabula
Akron
Canton
Chardon
Cleveland
Elyria
Kent
Ravenna
Lisbon
Lorain
Massillon
Medina
Mentor
Painesville
Warren
Wooster
Youngstown
OHIO Counties:
Ashtabula
Columbiana
Cuyahoga
Geauga
Lake
Lorain
Mahoning
Medina
Portage
Stark
Summit
Trumbull
Wayne

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Click MAP ICON for full size YPS Service Areas
Click for large map of Local & Wider Service Areas of YPS Integrated Systems for Fire Alarm Systems & Integrated Systems

Ohio Fire Alarm Service


Welcome
to both clients and prospective clients...

    How may we help you?
             
       What is it that you are looking for?


IMPORTANT NOTE:  Fire alarm codes in Ohio have recently changed. There are new requirements that must be followed. Please contact us regarding what must be done to be in compliance and to avoid problems. Codes are in force now. Contact us.


Fire Alarm System Certified Testing & Inspection Servicesstrobe:  Fire alarm sensors:  Radionics Dealer, fire alarm systems ohio

[D9124 Fire Control Panel] Radionics fire alarm panel, fire alarm systems ohioFOR ANY MAKE OF FIRE ALARM SYSTEM YPS INTEGRATED SYSTEMS can provide Certified Testing & Inspection Services, and is fully licensed by the State Fire Marshal, State of Ohio, to do so in Ohio. Our technicians are very experienced, fully trained, and provide services thoroughly and efficiently. If you are located within our Ohio Service Area - see Service Area Map, upper right on this page - we can provide you with professional service. Please contact us


LICENSED by the
State Fire Marshal, State of Ohio

YPS INTEGRATED SYSTEMS is a leading full service security firm providing design, sales, installation, integration, UL monitoring, testing, inspection, and service of fire alarms and related systems

 

We Serve the Fortune 100 and Small Business alike...

  • Commercial

  • Industrial

  • Institutional

  • Governmental

  • Retail

...a broad range of clients

New Fire Alarm System or Upgrade?

  • Purchase and install a new fire alarm system with automatic fire detection, or upgrade an aging fire system limited by older technology:  We can survey your facility and recommend a system that is custom designed and based upon your needs, situation, and budget. We can provide you with options to consider, and provide full UL monitoring in our own facility located right here in Northeast Ohio, and service and maintenance for the long haul. For more, click: Fire Alarm System Overview or please scroll down on this page for an overview and/or contact us to discuss what you are looking to do. We're here to help you with your fire detection system if you're located within our Local & Wider Service Areas - click map icon, upper right, this page.

Fire Alarm System Service and UL Fire Alarm Monitoring?

  • Service and/or monitoring of your fire alarm system because your alarm company went out of business or you're very dissatisfied:  Talk with us. If you want the stability and responsive, long term service that a major provider has to offer, talk with us at YPS. We've been providing reliable, excellent, and courteous service to clients for almost 50 years, and we are frequently contacted in these situations. Please contact us and describe your situation, and we'll determine how best we can help you. If you're located within our Local & Wider Service Areas - click map icon, upper right, this page - we'll be happy to be of service if possible. NOTE:  While we can monitor, test, inspect, or certify any fire alarm system, we are not able to service systems of several manufacturers because they are proprietary and we are not able to obtain parts. Please inquire and we'll help determine what is possible. Contact us.

A Note on Radionics and Bosch:  We are a major BOSCH Certified Security Dealer. Bosch purchased Radionics years ago now and has incorporated and integrated the Radionics fire detection and alarm system product lines, and others, into the complete BOSCH product line. If you know the reputation of Radionics and you're looking for a Radionics system, Radionics is now BOSCH. YPS INTEGRATED SYSTEMS formerly was a Radionics dealer.

 

FIRE ALARM SYSTEM OVERVIEW:  UL, NFPA

Bosch fire alarm control panels and fire product accessories meet the most demanding industry requirements. Through Bosch's participation on Underwriters Laboratory (UL) and NFPA code committees, they are not only aware of new codes, but have been instrumental in creating new standards for the fire alarm industry. These new standards are the cornerstone of the Bosch fire product line. 

[D9124 Fire Control Panel] Radionics Dealer, fire alarms systems ohio
Bosch offers a broad line of fire alarm control equipment ranging from a 3-zone Digital Alarm Communicator Transmitter (DACT) to the high-end integrated, intelligent fire alarm controls. Each system is designed to provide accurate, local response to all types of fire hazards. Using the latest communications technology, this critical information is processed and transmitted to responding agencies. The fire alarm system can also interface with other building functions during an emergency, for example, it can control the heating and ventilation systems, or unlock doors on an access control system. 

As well as providing reliable fire detection capabilities, Bosch fire alarm systems can also be used as integrated controllers for intrusion and access control systems.

The latest development in the Bosch fire product line is a series of analog fire control systems. The use of analog technology allows improved system expansion and networking capabilities for up to tens of thousands of detection points.
 
The Bosch fire product line includes a wide range of accessories to meet most fire detection applications. All devices are UL Listed and compatibility listed with the appropriate Bosch fire alarm control panel.
 

Integrated, Addressable Fire Alarm Reporting Systems, Elements

 

FIRE ALARM PANELS

Bosch provides complete Fire Alarm System solutions. Bosch panels cover all types of job requirements from small conventional systems to large analog detection networks. As an authorized dealer, YPS INTEGRATED SYSTEMS can help you select a Bosch Fire System to meet all your project and budget needs.
 

Notes on ADDRESSABLE FIRE ALARM PANELS

Addressable fire alarm systems support a variety of installation applications. Many are CSFM and FM approved and conform to NFPA 72. Schools, universities, manufacturing plants and healthcare facilities are some of the more complex installations it is designed to support. You can also choose from a diverse line of Bosch initiating and indicating devices, all backed by an industry reputation for quality. UL Listed for fire, intrusion and fire/intrusion combination. 
 
Accurate information from individual points is communicated to the central station monitoring facility. The detailed reporting capability of a number of panels provide a solution to system service and maintenance problems. The silencing of a "troubled" condition is a common occurrence with fire alarm systems. With certain panels, a maintenance person won't be able to silence a "trouble" condition and forget about it. The location and time of the "trouble" will be reported to the central station and the required action can be taken. The base system configuration supports a high number of points of detection or supervision. Optional accessory modules can expand a system's capability with up to 2,400 detection devices utilizing up to 246 individual reporting addresses. Capabilities and expansion depend upon the panel that is selected.

 

PROFESSIONAL FIRE ALARM SYSTEMS:  ADDRESSABLE REPORTING CAN SAVE LIVES AND PROPERTY


If a fire alarm is initiated at your location, we'll know the exact point where the alarm originated. And we'll know what kind of event has occurred. That precision can save precious time when firefighters arrive. It is a life safety issue.

Where do you go from here? Some choices or suggestions:

  • Questions? There's nothing to lose by talking with us and discussing what's possible - Contact options here
  • See more? Check out services on other pages - start here - YPS Home Page or back to page top
  • UL Monitoring? Check out our 24/7 monitoring of systems in our LOCAL central station that YPS owns and operates and controls - see our Central Station page
  • Make sure that we serve your geographic location? Click map icon at left.
  • Make a comment or suggestion on the material above if something was clear and understandable, or wasn't clear and it was confusing; comment on our website or on anything you care to comment on and send this to YPS management. Comment Page

    Thank you for visiting, for contacting us, and for any comments. - - YPS Management
  • 040800

    Contact YPS for all your fire alarm, security, and integrated system needs. For more on these systems, or to contact or telephone a representative, click here > MORE.

    [back to top]

        Leader in Integrated Security Since 1962                                                                         Location  > 

    AUTOMATIC FIRE DETECTION


    Logo YPS Integrated Systems:  Fire Alarms, Intrusion Detection/Security Alarms, Access Control, Video Surveillance Camera Systems,  Click logo to go to YPS Home Page               YPS Integrated Systems is a  BOSCH Certified Security Dealer - logo
    .

    COMPANY
    EMAIL

                           SITE REVIEW:  6-30-2008                                                                      For PA & All Ohio Offices:   800-544-9591


    | PRIVACY & OTHER YPS POLICIES |

    Questions, comments, suggestions, or problems on this website:
    WEBMASTER EMAIL

    Mail (main office)
    P.O. Box 980, Warren, OH 44482-0980
    Main Office Location: 
    164 Elm Street, S.E., Warren, OH 44483
    Cleveland Ohio Office (Solon):
    (all mail to the mail address above)



    Powered by
    Web Services by Hawkeye Services:  Design, Copy, Graphics, Maintenance, Hosting




    Best viewed
    & optimized for

    1280 x1024
     or above

    Copyright © 2000-2008, All Rights Reserved